B-69BMitutoyo reserves the right to change any or all aspects of any product specication, including prices, designs and service content, without notice.B-69B5. Wipe away any dust, chips and other debris from the circumference and measuring face of the spindle as part of daily maintenance. In addition, sufciently wipe off any stains and ngerprints on each part with dry cloth.6. Use the constant-force device correctly so that measurements are performed with the correct measuring force.7. When attaching the micrometer onto a micrometer stand, the stand should clamp the center of the micrometer frame. Do not clamp it too tightly.8. Be careful not to drop or bump the micrometer on anything. Do not rotate the micrometer thimble using excessive force. If you believe a micrometer may have been damaged due to accidental mishandling, ensure that it is inspected for accuracy before further use.9. After a long storage period, or when there is no protective oil lm visible, lightly apply anti-corrosion oil to the micrometer by wiping with a cloth soaked in it.10. Notes on storage:・ Avoid storing the micrometer in direct sunlight.・ Store the micrometer in a ventilated place with low humidity.・ Store the micrometer in a place with little dust.・ Store the micrometer in a case or other container, which should not be kept on the oor.・ When storing the micrometer, always leave a gap of 0.1 to 1 mm between the measuring faces.・ Do not store the micrometer in a clamped state.4. Wipe off the measuring faces of both the anvil and spindle with lint-free paper set the start (zero) point before measuring.Testing Parallelism of Micrometer Measuring FacesParallelism can be estimated using an optical parallel held between the faces. First, wring the parallel to the anvil measuring face. Then close the spindle on the parallel using normal measuring force and count the number of red interference fringes seen on the measuring face of the spindle in white light. Each fringe represents a half wavelength difference in height (0.32 μm for red fringes).In the above gure a parallelism of approximately 1 µm is obtained from 0.32 µm×3=0.96 µm.Optical parallel reading direction on the spindle sideOptical parallelアンビル側Fringes on the spindle sideGeneral Notes on Using the Micrometer1. Carefully check the type, measuring range, accuracy, and other specications to select the appropriate model for your application.2. Leave the micrometer and workpiece at room temperature long enough for their temperatures to equalize before making a measurement.3. Look directly at the ducial line when taking a reading against the thimble graduations. If the graduation lines are viewed from an angle, the correct alignment position of the lines cannot be read due to parallax error.SleeveThimble(c)(b)(a)(b) Looking directly at the index line(c) From below the index line(a) From above the index lineTesting Flatness of Micrometer Measuring FacesMeasuring face is curved by approximately 1.3 μm. (0.32 μm×4 paired red fringes.)Measuring face is concave (or convex) approximately 0.6 μm deep. (0.32 μm×2 continuous fringes)Optical atOptical atAnvilAnvilInterference fringe reading direction

元のページ  ../index.html#126

このブックを見る