MEASURING INSTRUMENTS CATALOG No.E2021
357/604

F-16FMitutoyo reserves the right to change any or all aspects of any product specication, including prices, designs and service content, without notice.Functions• Calculation f (x’) =Ax’+B+Cx’–1 (x’=x+offset)• Peak detection (MAX/MIN)• Runout (MAX - MIN) HoldNote: Peak detection 1) Sampling rate: 10 readings/sec 2) Capturing speed: 10 µm/sec (max.)Settings can be changed to:1) Sampling rate: 50 readings/sec2) Capturing speed: 50 µm/sec (max.)• Zero-setting (INC system)• Preset (ABS system)• Tolerance judgment (P1, P2, P3, and INC can be stored)• Analog bar resolution selectable• Key lock• Display hold (when no external device is connected)• Data output• External PC setting input• Display rotation (330°)• Low battery voltage alarm display• Error alarm display• Resolution switching** Since the calculation resolution is one micrometer (0.001 mm), using sub-micrometer resolution settings may result in the 4th-place digit being unreliable, particularly when B is set to a very low value and C=0. It does not change at all with certain combinations of calculation coefcient (for example, A=1, B=C=0). The 3rd-place digit representing micrometers (if displayed) is always reliable.Optional Accessories• Lifting Lifting lever21EZA198 (ISO/JIS Type), 21EZA199 (ASME/ANSI/AGD Type) Lifting knob21EZA105 (ISO/JIS Type), 21EZA150 (ASME/ANSI/AGD Type) Lifting cable21JZA295• SPC Cable: 905338 (1 m) 905409 (2 m)• USB Input Tool Direct (2 m): 06AFM380F• Input Tool Series IT-016U (USB Keyboard Signal Conversion Type): 264-016-10 IT-007R (RS-232C Communication Conversion Type): 264-007• Connecting Cables for U-WAVE-T (160 mm): 02AZD790F For foot switch: 02AZE140F• Digimatic Mini-Processor DP-1VA LOGGER: 264-505• Parameter setup kit: 21EZA313Note: Parameter setting software (can be downloaded for free from the Mitutoyo website) is also required.Resolution (mm)0.00020.0050.10.00050.010.20.0010.020.50.0020.051Resolution (in)0.000010.00020.0050.000020.00050.010.000050.0010.020.00010.0020.05An inspection certicate is supplied as standard. Refer to page U-9 for details.Products equipped with the measurement data output function can be connected to the measurement data network system MeasurLink® (refer to page A-25 for details).ABSOLUTE Digimatic Indicator ID-CSERIES 543 — Calculation Type• The ABS (absolute) scale restores the last origin position*1 automatically when the indicator is turned on, and realizes high reliability by eliminating over-speed errors.• By using the parameter setup kit (optional) and the dedicated software, the functions and the parameters can be congured using a computer.• Equipped with a data output port that enables incorporation into measurement networking and statistical process control systems. (Refer to page A-3)*1 Regarding origin setting, refer to “Origin Setting of Digimatic Indicators” on page F-25.Digimatic IndicatorsComparison measuring instruments which ensure high quality, high accuracy and reliability.SPECIFICATIONSMetricOrder No.Range (mm)Resolution (selectable)Maximum permissible error*2 (mm)Measuring force MPL (N)Power supplyBattery life (normal use)*5Net mass (g)MPEE*3Hysteresis MPEHRepeatability MPER543-340B12.712 steps*50.0030.0020.0021.5 or lessCR2032×1 pc.Approx. 1 year170543-590B25.41.8 or less*4190543-595B50.80.0062.3 or less*4260Inch/MetricOrder No.RangeResolution (selectable)Maximum permissible error*2Measuring force MPL (N)Power supplyBattery life (normal use)*5Net mass (g)MPEE*3Hysteresis MPEHRepeatability MPER543-341B0.5 in/12.7 mm12 steps*5±0.0001 in /0.003 mm0.0001 in /0.002 mm0.0001 in /0.002 mm1.5 or lessCR2032×1 pc.Approx. 1 year170543-342B543-591B1 in/25.4 mm1.8 or less*4190543-592B543-596B2 in/50.8 mm±0.00025 in /0.006 mm2.3 or less*4260543-597B*2 Valid for resolution set to 0.001 mm/0.00005 in and coefcients A=1, B=0 and C=0.*3 Error of indication for the total measuring range*4 Applies for a spindle orientation between the spindle pointing vertically downward to the spindle horizontal.*5 Applies only if not connected to a data processor. Battery life depends on use of the indicator. Use the above value as a guide only.Note: Flat back type only.• Calculation function operates on spindle displacement. Entering the appropriate formula factors for a xture dedicated to the application enables direct measurement readout, thereby eliminating any need for the conversion tables previously needed for those applications where xtures are typically used.• Five buttons, status icons, and clear button indications allow for easy operation of a wide variety of functions.• Wide LCD and new analog bar graph are now standard on all models.543-342B ISO/JIS type ASME/ANSI/AGD type

元のページ  ../index.html#357

このブックを見る