MEASURING INSTRUMENTS CATALOG No.E2021
436/604

F-95FMitutoyo reserves the right to change any or all aspects of any product specication, including prices, designs and service content, without notice.FMaximum permissible error(unit: µm)Maximum permissible error (MPE) by measurement characteristics - dial indicators with bezel dia. 50 mm or largerMaximum permissible error (MPE) by measurement characteristics - dial indicators with bezel dia. 50 mm or smaller and Back Plunger type dial indicatorsGraduation (mm)0.010.0050.0010.010.0050.0020.001Measuring range (mm)1 or lessOver 1 and up to 3Over 3 and up to 5Over 5 and up to 10Over 10 and up to 20Over 20 and up to 30Over 30 and up to 50Over 50 and up to 1005 or less1 or lessOver 1 and up to 2Over 2 and up to 51 or lessOver 1 and up to 3Over 3 and up to 5Over 5 and up to 105 or less1 or less1 or lessRetrace error33335789322344453.52.52Repeatability 3333455530.50.513333311Arbitrary 1/10 revolution 555581010125223.5888962.52.5Arbitrary 1/2 revolution88991012121793.5451111121294.54Arbitrary One revolution 8910101515152010456121214141054.5Entire measuring range810121525304050125710151618201265Note 1: The maximum permissible error (MPE) for one-revolution dial indicators does not specify the indication error of an arbitrary 1/2 and 1 revolution. Note 2: The MPE represents the value at 20 ºC, which JIS B 0680 denes as the standard temperature.Note 3: The measurement characteristics of a dial indicator have to meet both maximum permissible error (MPE) and measurement force permissible limits (MPL) at any position within the measuring range in any posture when the measurement characteristics are not specied by the manufacturer.Indication errorMitutoyo's Response to Dial Indicator Standard B 7503: 2017•We guarantee the accuracy of completed products by inspecting them in the vertical posture. Standard-attached inspection certicate includes inspection data.•We issue paid-for inspection certicates for horizontal or opposite posture if required.•It is said that, for evaluation of the compatibility to the specications, JIS B 0641-1 or the criteria where the internationally-recognized specication range and the OK range are equal shall be applied. Also, it is said that the uncertainty is preferred to be evaluated based on ISO 14253-2 and ISO/IEC Guide 98-3. Therefore, we perform shipping inspection of dial indicators inclusive of the uncertainty of calibration as in the past.Dial test indicator (lever type) Standard B7533: 2015 (Extract from JIS/Japanese Industrial Standards)No.Item.Measuring methodMeasuring pointEvaluation methodDiagram1Error of indication over a range of Measuring rangeHolding the dial test indicator (lever type), dene the reference point at near the contact point resting point where the indication and error of indication is set zero.Then, move the contact point in the forward direction and read the error of indication at each measuring point.Next, after moving the contact point for more than three graduations from the end of the measuring range, move the contact point in the backward direction and read the error of indication at the same measurement point in the forward direction.(The forward direction is the direction against the measuring force to the contact point of the lever-operated dial indicator; the backward direction is the measuring force applied direction.)Per 10 graduations in the forward and backward direction from the reference point to the end point.Obtain the difference between the maximum and the minimum values of indication error of all measurement points in the forward direction.2Error of indication over a range of 10 scale divisionsIn the forward direction from the reference point to the end point, obtain the maximum difference of the indication error among the adjacent measurement points per 10 graduations.3Error of indication over a range of One revolutionIn the forward direction from the reference point to the end point, obtain the maximum difference of the maximum and the minimum indication errors to be read by the zero-point xed method over the measuring range per 1 revolution.4HysteresisObtain the maximum difference in reference to the indication error at the same measuring point in both forward and backward directions among all the measurement points.5RepeatabilityHolding the dial test indicator (lever type) with its contact point parallel with the top face of the measuring stage, move the contact point quickly and slowly ve times at a desired position within the measuring range and read the indication at each point.At arbitrary points within the measuring rangeObtain the maximum difference of the ve measured values.6Measuring forceHolding the dial test indicator (lever type), move the contact point in the forward and backward directions continuously and gradually, and read the measuring force in the measuring range.Reference point and end point within the measuring rangeObtain the maximum and the minimum values in reference to the measuring force.Dial test indicator (lever type)SupportingstandMicrometer head orlength measuring unit Dial test indicator (lever type)SupportingstandDial test indicator (lever type)Top pan type spring scale  F-95

元のページ  ../index.html#436

このブックを見る