MEASURING INSTRUMENTS CATALOG No.E2021
464/604

G-27GLaser Scan MicrometerNon-contact, high-speed, high-precision measurementMitutoyo reserves the right to change any or all aspects of any product specication, including prices, designs and service content, without notice.Cable spaceMeasuring range(Measuring position)M3, depth 6 (×4)ø3.1, depth 65512618121343246103Min. 702532.5844015.510.517.51111Working distance40LSM-500S Measuring UnitSERIES 544 — 5 μm to 2 mm Measuring Unit•Capable of measuring down to 5 µm outside diameter.•Provides ultra-high accuracy of ±0.3 µm over the entire measuring range (5 µm to 2 mm).Optional Accessories• Multifunctional display unit, LSM-6200: • Panel-mount type display unit, LSM-5200:• Standard calibration gage set (ø0.1, ø2.0): 02AGD110• Guide pulley: 02AGD200• Air blower: 02AGD220• Extension signal cable (max. 15 m) Order No.Cable length02AGN780A5 m02AGN780B10 m02AGN780C15 mOrder No.Remarks544-046Japanese user's manual544-047English user's manualOrder No.Display typeRemarks544-071Japanese mm/EJapanese user's manual544-071*English mm/EEnglish user's manual544-072*English mm/in* To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE."SPECIFICATIONSOrder No.544-531544-532Applicable laser standardsJISIEC, FDAUser's ManualJapanese versionEnglish versionMeasuring range0.005 to 2 mm*1Resolution0.01 to 10 µm (selectable)Repeatability*2±0.03 µmLinearity*3 (20 °C)±0.3 µmPositional error*4±0.4 µmMeasuring region*51×2 mm (0.005 to 2 mm)Scanning rate3200 scans/sLaser wavelength650 nm (Visible)Laser scanning speed76 m/sOperating environmentTemperature0 to 40 °CHumidityRH 35 to 85% (non-condensing)Protection LevelIP64*6*1 The measuring range for a transparent object is 0.05 mm to 2 mm. Please consult your local Mitutoyo office for objects smaller than 0.05 mm. The measuring range is 0.1 mm to 2 mm in the 1 to 255 edge measurement mode or when activating automatic workpiece detection. If using the optional dual connection unit for LSM-6200, the measuring range will be 0.05 mm to 2 mm.*2 Determined at the level of ±2 (: standard deviation) when measuring ø2 mm at the interval of 0.32 sec. (average 1024 times).*3 Applies at the center of the measuring range when measuring outside diameters.*4 An error in outside diameter measurement due to variation in workpiece position either in the optical axis direction or in the scanning direction.*5 The area defined by [optical axis depth]×[scanning width].*6 The protection level provided for the interior. If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction.Note: When using the extra-fine line measurement function (FINE), guide messages for setting the following will not be displayed: dual-measurement, segment designation, automatic workpiece detection, and group judgment. 8-M342645310.515.52250208410457.523012339683434*71048818.5404011040.538.5309.59.514.59.51506404015773ø3.1 hole, depth 6(Measuring position)Signal cableCable spaceRelay cableEmission UnitBaseMax. 100Measuring rangeReception UnitMeasuring positionM4, depth 8 (×3)M4, depth 8 (×3)To Reception Unit(Cable length 0.6 m)ø3.1 hole, depth 6ø3.1 hole, depth 6Dimension when disconnected (bottom view)Emission Unit: 0.7 kgReception Unit: 0.4 kgBase: 0.3 kgSignal cable (5 m): 0.5 kg*7 Extendable up to 66 mm.Min. 70DIMENSIONSUnit: mmDIMENSIONSUnit: mmLSM-501S Measuring UnitSERIES 544 — 50 μm to 10 mm Measuring Unit•Provides ultra-high accuracy of ±0.5 µm over the entire measuring range (0.05 to 10 mm).•The industry’s rst narrow-range accuracy performance in this measuring range of ±(0.3+0.1D) μm is available for high-accuracy measurement.Optional Accessories• Multifunctional display unit, LSM-6200:• Panel-mount type display unit, LSM-5200: • Standard calibration gage set (ø0.1, ø10.0): 02AGD120• Wire guiding pulley: 02AGD210• Adjustable workstage: 02AGD400• Air blower: 02AGD230• Workstage: 02AGD270• Extension signal cable (max. 15 m)SPECIFICATIONSOrder No.544-533544-534Applicable laser standardsJISIEC, FDAUser's ManualJapanese versionEnglish versionMeasuring range0.05 to 10 mmResolution0.01 to 10 µm (selectable)Repeatability*1±0.04 µmLinearity*2 (20 °C)Whole range±0.5 µmNarrow range±(0.3+0.1D) µm*3Positional error*4±0.5 µmMeasuring region*52×10 mm (0.05 to 0.1 mm) 4×10 mm (0.1 to 10 mm)Scanning rate3200 scans/sLaser wavelength650 nm (Visible)Laser scanning speed113 m/sOperating environmentTemperature0 to 40 °CHumidityRH 35 to 85% (non-condensing)Protection LevelIP64*6*1 Determined at the level of ±2 (: standard deviation) when measuring ø10 mm at the interval of 0.32 sec. (average 1024 times).*2 Applies at the center of the measuring range when measuring outside diameters.*3 D=Difference in diameter between the master gage and workpiece. (Unit: mm)*4 An error in outside diameter measurement due to variation in workpiece position either in the optical axis direction or in the scanning direction.*5 The area defined by [optical axis depth]×[scanning width].*6 The protection level provided for the interior. If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction.Order No.Cable length02AGN780A5 m02AGN780B10 m02AGN780C15 m• Extension relay cableOrder No.Cable length02AGC150A1 mOrder No.Remarks544-046Japanese user's manual544-047English user's manualOrder No.Display typeRemarks544-071Japanese mm/EJapanese user's manual544-071*English mm/EEnglish user's manual544-072*English mm/in* To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE."With signal cable (5 m) 02AGN770AWith signal cable (5 m) 02AGN770A

元のページ  ../index.html#464

このブックを見る