MEASURING INSTRUMENTS CATALOG No.E2021
465/604

G-28GMitutoyo reserves the right to change any or all aspects of any product specication, including prices, designs and service content, without notice.ø3.18-M3805.510525054.584.54242170558050*788482594857202618.5502210.515.59.59.514.59.541579012110902010303554653684295.565.515057.5130(Measuring position)Signal cableMin. 70Cable spaceRelay cableEmission UnitMax. 350Measuring rangeMeasuring rangeReception UnitBaseM4, depth 8, ø3.3 through hole (×3)For mounting side plate (same in the back)M4, depth 8, ø3.3 through hole (×2)For mounting side plate (same in the back)To Reception Unit(Cable length 1.4 m) ø3.1, depth 6 (Reference hole)M4, depth 8 (×3)For mounting base ø3.1, depth 6 (Reference hole)M4, depth 8 (×3)For mounting baseDimension when disconnected (bottom view)Emission Unit: 1.1 kgReception Unit: 0.6 kgBase: 0.5 kgSignal cable (5 m): 0.5 kg*7 Extendable up to 270 mm12-M3ø3.115.510.5110*716388192348662060424218.59036090225010058707258102540185822011013012115.571797168.587874214.59.5162174.5121639.59.5273(Measuring position)Signal cableMin. 70Cable spaceReception UnitRelay cableEmission UnitMax. 700Measuring rangeMeasuring rangeBaseM5, depth 10, ø4.2 through hole (×3)For mounting side plate (same in the back)M5, depth 10, ø4.2 through hole (×2)For mounting side plate (same in the back)To Reception Unit(Cable length 1.4 m) ø3.1, depth 6 (Reference hole)M5, depth 10 (×3)For mounting base ø3.1, depth 6 (Reference hole)M5, depth 10 (×3)For mounting baseDimension when disconnected (bottom view)Emission Unit: 1.4 kgReception Unit: 0.8 kgBase: 0.8 kgSignal cable (5 m): 0.5 kg*7 Extendable up to 537 mmDIMENSIONSUnit: mmDIMENSIONSUnit: mmLSM-503S Measuring UnitSERIES 544 — 0.3 mm to 30 mm Measuring Unit•Ensures ±1.0 µm accuracy over the entire measuring range (0.3 to 30 mm).•The industry’s rst narrow-range accuracy performance in this measuring range of ±(0.6+0.1D) μm is available for high-accuracy measurement.Optional Accessories• Multifunctional display unit, LSM-6200:• Panel-mount type display unit, LSM-5200: • Standard calibration gage set (ø1.0, ø30.0): 02AGD130• Adjustable workstage: 02AGD490• Air blower: 02AGD240• Workstage: 02AGD270• Extension signal cable (max. 25 m)Optional Accessories• Multifunctional display unit, LSM-6200:• Panel-mount type display unit, LSM-5200: • Standard calibration gage set (ø0.1, ø60.0): 02AGD140• Adjustable workstage: 02AGD520• Air blower: 02AGD250• Extension signal cable (max. 25 m)Order No.Cable length02AGN780A5 m02AGN780B10 m02AGN780C15 m02AGN780D20 mOrder No.Cable length02AGN780A5 m02AGN780B10 m02AGN780C15 m02AGN780D20 m• Extension relay cable (max. 5 m)02AGC150A1 m02AGC150B3 m02AGC150C5 m• Extension relay cable (max. 5 m)02AGC150A1 m02AGC150B3 m02AGC150C5 mSPECIFICATIONSOrder No.544-535544-536Applicable laser standardsJISIEC, FDAUser's ManualJapanese versionEnglish versionMeasuring range0.3 to 30 mmResolution0.02 to 100 µm (selectable)Repeatability*1±0.11 µmLinearity*2 (20 °C)Whole range±1.0 µmNarrow range±(0.6+0.1D) µm*3Positional error*4±1.5 µmMeasuring region*510×30 mm (0.3 to 30 mm)Scanning rate3200 scans/sLaser wavelength650 nm (Visible)Laser scanning speed226 m/sOperating environmentTemperature0 to 40 °CHumidityRH 35 to 85% (non-condensing)Protection LevelIP64*6*1 Determined at the level of ±2 (: standard deviation) when measuring ø30 mm at the interval of 0.32 sec. (average 1024 times).*2 Applies at the center of the measuring range when measuring outside diameters.*3 D=Difference in diameter between the master gage and workpiece (Unit: mm)*4 An error in outside diameter measurement due to variation in workpiece position either in the optical axis direction or in the scanning direction.*5 The area defined by [optical axis depth]×[scanning width].*6 The protection level provided for the interior. If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction.Order No.Remarks544-046Japanese user's manual544-047English user's manualOrder No.Remarks544-046Japanese user's manual544-047English user's manualOrder No.Display typeRemarks544-071Japanese mm/EJapanese user's manual544-071*English mm/EEnglish user's manual544-072*English mm/in* To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE."Order No.Display typeRemarks544-071Japanese mm/EJapanese user's manual544-071*English mm/EEnglish user's manual544-072*English mm/in* To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE."LSM-506S Measuring UnitSERIES 544 — 1 mm to 60 mm Measuring Unit•Ensures ±3 µm accuracy over the entire measuring range (1 to 60 mm).•The industry’s rst narrow-range accuracy performance in this measuring range of ±(1.5+0.5D) μm is available for high-accuracy measurement.SPECIFICATIONSOrder No.544-537544-538Applicable laser standardsJISIEC, FDAUser's ManualJapanese versionEnglish versionMeasuring range1 to 60 mmResolution0.05 to 100 µm (selectable)Repeatability*1±0.36 µmLinearity*2 (20 °C)Whole range±3 µmNarrow range±(1.5+0.5D) µm*3Positional error*4±4 µmMeasuring region*520×60 mm (1 to 60 mm)Scanning rate3200 scans/sLaser wavelength650 nm (Visible)Laser scanning speed452 m/sOperating environmentTemperature0 to 40 °CHumidityRH 35 to 85% (non-condensing)Protection LevelIP64*6*1 Determined at the level of ±2 (: standard deviation) when measuring ø60 mm at the interval of 0.32 sec. (average 1024 times).*2 Applies at the center of the measuring range when measuring outside diameters.*3 D=Difference in diameter between the master gage and workpiece (Unit: mm)*4 An error in outside diameter measurement due to variation in workpiece position either in the optical axis direction or in the scanning direction.*5 The area defined by [optical axis depth]×[scanning width].*6 The protection level provided for the interior. If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction.With signal cable (5 m) 02AGN770AWith signal cable (5 m) 02AGN770A

元のページ  ../index.html#465

このブックを見る