MEASURING INSTRUMENTS CATALOG No.E2021
467/604

G-30GMitutoyo reserves the right to change any or all aspects of any product specication, including prices, designs and service content, without notice.Optional Accessories• Standard calibration gage set (ø1.0, ø25.0): 02AGD180• Workstage: 02AGD270• Adjustable workstage : 02AGD280ø3.1Min. 70Cablespace 10.5770563525585017015.590200420701907070907411311Measuring range(Center of measuring stroke)100120606050228×M315(Measuring position)External DimensionsUnit: mmLSM-6902H Measuring Unit and 6900 DisplaySERIES 544 — 0.1 mm to 25 mm High Accuracy• Demonstrates the best repeatability available in the 25 mm class.• The ultra-precise scanning motor enables the highest measurement accuracy to be realized.• Thanks to excellent linearity, an accuracy of ±0.5 µm over the entire measuring range and a higher accuracy of ±(0.3+0.1D) µm over a narrow range are guaranteed.• The optimal solution for measuring the outside diameter of pin gages or plug gages.SPECIFICATIONSSet Order No.544-497-1544-498-1*6544-499-1*6Measuring unitTypemmmminch/mmApplicable standards JISIEC, FDA Measuring range0.1 to 25 mm (0.004 to 1.0 in)Resolution0.01 to 10 µm (selectable) (0.000001 to 0.0005 in)Repeatability*1Whole range±0.045 µm (±0.0000018 in) (ø25 mm)Narrow range±0.03 µm (±0.0000012 in) (ø10 mm)Linearity*2 (20 °C)Whole range±0.5 µm (±0.000020 in)Narrow range±(0.3+0.1D) µm±(0.000012+0.01D) inch*5Positional error*3±0.5 µm (±0.000020 in)Measuring region*4±1.5 mm×25 mm (±0.006×1.0 in)Scanning rate3200 scans/sLaser wavelength650 nm (Visible)Laser scanning speed226 m/sOperating environmentTemperature0 to 40 °CHumidityRH 35 to 85% (non-condensing)*1 ±2 values ( being the standard deviation) for when ø25 mm and ø10 mm samples are measured for 1.28 seconds (2048 scans on average, 2 samples).*2 The value at the center of the measuring range.*3 An error in outside diameter measurement due to variation in workpiece position either in the optical axis direction or in the scanning direction.*4 The region defined by [optical axis depth]×[scanning width].*5 D=Difference in diameter between the master gage and workpiece (Unit: mm).*6 To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE.Display unitDisplay16-digit plus 11-digit fluorescent display, and guide message LEDSegment1 to 7 (1 to 3, transparent) or 1 to 255 edgesAveraging timesArithmetic average: 2 to 2048 scans. Moving average: 32 to 2048 scans.JudgmentSelection from "target value + tolerance", "lower tolerance + upper tolerance", or "7 classes multilimit tolerance zone".Measurement modeStandby, Single measurement, Continuous measurementExternal dimensions335 (W) ×134 (H) ×250 (D) mmPower supply100 to 240 VAC ±10% 30 W 50/60 HzStandard I/FRS-232C, Analog I/OOptional I/FDigimatic code output unit (2-ch), 2nd I/O analog I/F, BCD I/FOperating environment0 to 40 °C, RH 35 to 85% (non-condensing)OthersNominal setting, sample setting, suppression of unnecessary digits, transparent object measurement, automatic measurement in edge mode, output timer, abnormal data elimination, SHL change, group judgment, simultaneous measurement, statistical processing, mastering, buzzer function, automatic workpiece detection (dimension/position), zero-set/offsetNote: In the case of dual measuring-unit connection, extra-fine line measurement and some of the communication commands are not availableLSM-6902HLSM-9506 Integrated Display/Measuring UnitSERIES 544 — 0.5 mm to 60 mm High Accuracy•High accuracy of ±2.5 µm, integrated display unit with many functions equivalent to the multi-function display unit. (Some functions may be unavailable.)ø3.1 (Measuring position)12-M3Measuring range80Cable space18011256098100502264760120101188236552.540382851805282021110.515.51010010150839710010017213.5DIMENSIONSUnit: mmOptional Accessories• Standard calibration gage set (ø1.0, ø60.0): 02AGD170• Adjustable workstage Horizontal stroke 200 mm: 02AGD370 Horizontal stroke 300 mm: 02AGD680SPECIFICATIONSOrder No.544-115*5544-116*6Typemminch/mmMeasuring range0.5 to 60 mm0.02 to 2.36 in/0.5 to 60 mmResolution0.05 to 100 µm (selectable)0.000002 to 0.005 in/0.00005 to 0.1 mmRepeatability*1±0.6 µm (±0.00003 in)Linearity*2 (20 °C)±2.5 µm (±0.0001 in)Positional error*3Optical axis direction±2.5 µm (±0.0001 in)Scanning direction± (2.0+L/10) μmL: Displacement between workpiece center and optical axis centerMeasuring region*3±5×60 mm (±0.2×2.36 in)Scanning rate1600 scans/sLaser wavelength650 nm (Visible)*4Laser scanning speed226 m/s (8900 in/s)Display unit16-digit dot matrix (upper column) +7 segment 11-digit (lower column), guidance LEDsStandard interfaceRS-232C, Digimatic code output unit (1-ch)Optional interfaceNoPower supplyAC100 V to 240 V±10%, 25 W, 50/60 HzOperating environment0 to 40 °C, RH 35 to 85% (non-condensing)*1 Determined at the level of ±2 (: standard deviation) when measuring ø60 mm in the interval of 0.32 sec. (average 512 times).*2 Applies at the center of the measuring range when measuring outside diameters.*3 An error in outside diameter measurement due to variation in workpiece position either in the optical axis direction or in the scanning direction.*4 FDA Class II (544-116-1A)/IEC Class 2 (All models except 544-116-1A) semiconductor laser for scanning (Maximum power: 1.0 mW)*5 To denote your AC power cable add the following suffixes to the order No.: D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE.*6 To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC and No suffix are required for PSE.Measuring UnitDisplay unit335134281.4131212258013.525125Cablespace Approx. 12°

元のページ  ../index.html#467

このブックを見る